Hall effect sensors

Application

The Mors Smitt transducers are used to measure high currents in rolling stock and track side applications. High currents are converted linear to low power signals.

Description

The transducers are based on compensating the magnetic field by a closed loop system.
The MSA range is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle pulsed currents.The MSA range is especially designed for secure measuring of a high permanent current. The current measuring range covers a bandwidth from -2000 A…2000 A.
The MSV range is used for the measurement of AC and DC voltages with high galvanic isolation between the current carrying conductor and output of the sensor. The voltage transducer can handle pulsed voltages.The MSV range is especially designed for secure measuring of a high permanent voltage. The current measuring range covers a bandwidth from -5000 V…5000 V.
  • MSA100 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and track side applications. High currents are converted lineair to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA100 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can…
  • MSA1000 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and trackside applications. High currents are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA1000 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle…
  • MSA200 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and trackside applications. High currents are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA200 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle…
  • MSA2000 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and trackside applications. High currents are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA2000 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle…
  • MSA2010 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents and high voltages in rolling stock and track side applications. High voltages or currents are converted linearly to low power signals. The sensors are based on compensating the magnetic field by a closed loop system. The MSA2010 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the…
  • MSA300 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and trackside applications. High currents are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA300 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle…
  • MSA500 – Hall effect transducer

    The Mors Smitt transducers are used to measure high currents in rolling stock and trackside applications. High currents are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSA500 is used for the measurement of AC and DC currents with high galvanic isolation between the current carrying conductor and output of the sensor. The current transducer can handle…
  • MSV100 – Hall effect transducer

    The Mors Smitt transducers are used to measure high voltages in rolling stock and trackside applications. High voltages are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSV100 is used for the measurement of AC and DC voltages with high galvanic isolation between the voltage carrying conductor and output of the sensor. The voltage transducer can handle…
  • MSV200 – Hall effect transducer

    The Mors Smitt transducers are used to measure high voltages in rolling stock and trackside applications. High voltages are converted linearly to low power signals. The transducers are based on compensating the magnetic field by a closed loop system. The MSV200 is used for the measurement of AC and DC voltages with high galvanic isolation between the voltage carrying conductor and output of the sensor. The voltage transducer can handle…